    Hepa Filters

Informations about HEPA FILTERS

    CleanZones Main service:Air shower, Clean rooms, Fume hoods, Laboratory furniture >> Products >> Hepa Filters >> HEPA FILTERS

HEPA FILTERS

High Efficiency Particulate Air (HEPA) and ULPA filters are manufactured utilizing the latest developments in filtration technology. Using the “Mini-Pleat” design, this microglass filter media pack is sealed to an anodized aluminum frame with a urethane-bonding agent. A neoprene gasket (SCE-43 grade ¼”x3/4”) with dovetailed corner joints is affixed to the frame to prevent air bypass. Each filter is individually tested with PSL (polystyrene latex spheres) and meet the specifications of Type C/ Type D as per the Institute of Environmental Sciences and Technology “Recommended Practice for HEPA/ULPA Filters” IEST-RP-CC001.3: HEPA AND ULPA FILTERS. HEPA filters are 99.99% efficient at the MPPS and; ULPA filters are available with 99.9995% at the MPPS.

The standard panel HEPA filters have a 2” media pack in a 3” deep frame. Filters are also available in 6” deep aluminum frames for older style units.

For special applications where the bora-silicia fibers of standard HEPA/ULPA filters represent a problem for trace metal applications, a PTFE media filter is available with an efficiency of 99.9995% on.07 microns.


High Efficiency Particulate Air (HEPA) and ULPA filters are manufactured utilizing the latest developments in filtration technology. Using the “Mini-Pleat” design, this microglass filter media pack is sealed to an anodized aluminum frame with a urethane-bonding agent. A neoprene gasket (SCE-43 grade ¼”x3/4”) with dovetailed corner joints is affixed to the frame to prevent air bypass. Each filter is individually tested with PSL (polystyrene latex spheres) and meet the specifications of Type C/ Type D as per the Institute of Environmental Sciences and Technology “Recommended Practice for HEPA/ULPA Filters” IEST-RP-CC001.3: HEPA AND ULPA FILTERS. HEPA filters are 99.99% efficient at the MPPS and; ULPA filters are available with 99.9995% at the MPPS.

The standard panel HEPA filters have a 2” media pack in a 3” deep frame. Filters are also available in 6” deep aluminum frames for older style units.

For special applications where the bora-silicia fibers of standard HEPA/ULPA filters represent a problem for trace metal applications, a PTFE media filter is available with an efficiency of 99.9995% on.07 microns.


Model

  Dimensions

W” x  L” x D”

1”SPWC rated CFM

StandardEfficiency

12X12X3F

12” x 12” x 3”

150

99.99%

12X24X3F

12” x 24” x 3”

300

99.99%

24X24X3F

24” x 24” x 3”

600

99.99%

24X36X3F

24” x 36” x 3”

900

99.99%

24X48X3F

24” x 48” x 3”

1220

99.99%

24X60X3F

24” x 60” x 3”

1525

99.99%

30X36X3F

30” x 36” x 3”

1125

99.99%

30X48X3F

30” x 48” x 3”

1520

99.99%

30X60X3F

30” x 60” x 3”

1920

99.99%

36X36X3F

36” x 36” x 3”

1350

99.99%

36X48X3F

36” x 48” x 3”

1850

99.99%

36X60X3F

36” x 60” x 3”

2250

99.99%

LFM-24

23 5/8” x 47 5/8” x 6”

1441

99.99%

LFM-22

23 5/8” x 23 5/8” x 6”

643

99.99%

Other sizes available upon request


request Info

640 Herman Road Ste 2 Jackson, NJ 08527   Phone Toll Free 888-399-2464 Local 732-534-5590  Fax 732-534-5589

 
 

 

 

 

 

 

 

 

Cleanzones is a leader in building clean rooms Softwall cleanroom and Hardwall cleanroom. Cleanzones builds clean room using Self-powered T-grid HEPA filter ceiling module, air shower, custom fume hoods or stock fume hoods. The fume hoods, exhaust fume hoods and laboratory fume hoods can be incorporated into any module we build.

By combining you cleanroom with exhaust fume hoods, Cleanzones can solve all your needs. Whatever the application for the clean room, we have the answer. From modular clean rooms to custom using Laminar flow work stations or a wet process station. Our wet process stations can include a wet bench.  Cleanzones can fulfill you needs for cleanrooms, portable clean rooms, Modular with pass through and wet process stations. Laminar flow hoods can be incorporated into our custom clean rooms. Our portable cleanroom can be made to your specs. Our portable clean rooms and modular can be incorporated with a wet process station, wet bench, laboratory furniture hood, fume exhaust hood, or an air shower. We also can make Negative flow exhaust workstation and containment work station. The containment work stations is a free-standing console design with a confined work chamber that prevents airborne powder/dust from contaminating the plant or lab atmosphere, or cross-contaminating other products in the air, and protects operator and plant facility.

Our Negative Flow Exhausting HEPA Filtered Workstation is a Free-standing console that provides containment of contaminated air through intake at work chamber. The initial prefilter collects gross contaminants, then the air passes through an exhaust HEPA filter (High Efficiency Particulate Air, 99.99% efficient on .3 microns) for removal of the remaining contaminants to .3 microns.

rss logo!!!!SUBSCRIBE TO OUR NEWS FEEDS BY CLICKING HERE  !!!!rss logo